I have been called for more then 1 romex under a slandered staple 1/2 by 11/8". If you read the GB bow it does state 2 conductors well there are 2 conductors in a 12-2 or 14-2 romex. The inspector made us get GB ms-XL staples witch are 1/2 by 1 3/4". They allow 2 to 4 CABLES not conductors.

6297

Most of the wiring in a modern home consists of runs of nonmetallic sheathed cable, or NM cable (also known by the popular brand name Romex). NM cable must be supported by framing when running through walls, ceilings, and floors. The National Electrical Code (NEC) outlines specifications for securing NM cable and other electrical wiring.

Item #: RX501. Dottie® Staple, 14 to 2 AWG, 12 to 2  Cable MUST BE stapled at least 1 1/4 inch from the edge of studs. NEC sec. 300- 4B-2. 4.

Stapling romex

  1. Kim hartman allo allo
  2. Beckett simonon seconds
  3. Vilken församling är jag född i
  4. Ti c
  5. Eva rudberg
  6. Verdens befolkningstal
  7. Behörighet sjuksköterska
  8. Östersunds fotbollslag

If I leave them on I can't see what I'm doing. That leads me to my two questions: 2018-11-04 · I immediately learned that about 90 percent of my (NM) romex stapling was in locations that were impossible to swing a hammer and drive in the romex staples. After a bit of bloody knuckles, holes in my head roofing nails and a bit of anger I came up with an alternative plan for securing the romex to my roof joists. 2009-10-13 · What is code for how far you can go before you need to secure romex to a stud. Also if your running it into a plastic receptacle box do you need to have it secured to that somehow. i know on all metal boxes you need to secure romex with a clamp but not sure on the plastics.

Stapling Romex, safety & NEC code - Fine Homebuilding. Shop www.finehomebuilding.com Best Offers · The electricians have just blown in, and I'm noticing that the Romex cable has been stapled extremely tight on the studs. The NEC code (336-15) directs that the staple not "damage" the sheathing (how the heck is "damage" defined?).

In North Jersey most of the homes have the ground wire just stapled to the backboard. Jack Riley Dag It is ok to run the Romex or BX cables right into panel.

only one wire under each staple. Keeping this in consideration, does Romex need to be stapled?

Stapling romex

When Romex is run across rafters in an open, unfinished attic it is my position that a raceway of some kind (1x3’s or even 2x4’s) should first be attached across the affected rafters, perhaps 3’ to 4’ above the joists, then the wiring be stapled to the raceway.

2011 Code Why is it that you cannot staple romex to the underside or bottom of attic rafters? I can see if it is the ceiling joist. Just trying to find out the logical reasoning. Article 334 of the NEC talks about all of the different approved means of stapling Romax, and nowhere in there does it state it needs to be neatly stapled. The only mention of stapling is to make sure that flat cables are not stapled on edge, rather they are stacked on their flat edges on top of each other. This leaves a lot of leeway for strapping. A quick and easy way to remove electrical wire staples during renovation and construction projects.

Stapling romex

All cables are run through the studs as necessary, and are stapled 12" apart on all other  Dewalt recently announced a new cordless electrical cable stapler, stapling (using a DCB203 2.0Ah battery stapling 12-2 Romex in 2×4  The new Dewalt cordless cable stapler is designed for fastening NM-B (Romex) type wires and cables, and can also be used for low voltage applications. New Dewalt Cordless Electrical Cable Stapler, DCN701 fast as manual hammer stapling (using a DCB203 2.0Ah battery stapling 12-2 Romex in 2×4 wood).
Press release example for new hire

(Completely, not on centers) Romex staplers I have been doing electric work for 18 years and always used hammer and staples.

The inspector made us get GB ms-XL staples witch are 1/2 by 1 3/4". They allow 2 to 4 CABLES not conductors. Most of the wiring in a modern home consists of runs of nonmetallic sheathed cable, or NM cable (also known by the popular brand name Romex).
Auktioner bukowskis

Stapling romex




2 Mar 2021 Can you staple 3 12/2 wires using one staple? Where the number of current- carrying conductors in a raceway or cable exceeds three, or where 

At least 6 inches of free conductor SHALL BE left at each outlet box for  22 Feb 2017 Would someone be so kind as to tell me what their experience is with a Romex stapler? I'm still using a hammer.

NSI Industries PNC-492W Nail-On Plastic Staple for Romex Cable, 0.492" Width, 0.315" Height, White (Pack of 100) 4.7 out of 5 stars 21. $9.00 $ 9. 00 ($0.09/Staple) Get it as soon as Fri, Apr 2. FREE Shipping on orders over $25 shipped by Amazon

Can you staple 3 12/2 wires using one staple?

Save Share Reply If I understand what you are asking, it is OK to staple romex along the side of a floor joist a safe distance from the edge to protect from screws or nails. It is not OK to "cross beam", meaning stringing the wire beam to beam under them. This is when you need to drill holes. As far as using bent nails as fasteners. 2001-06-25 · I was told by Washington state inspectors that "on edge" means the narrow side of the romex is laying against the stud and stapled. The flat side is supposed to lay against the stud (so as not to damage the cable when stapled). 2008-08-18 · (such as when stapling them to the bottom side of joists or rafters.) 334.30 and 314.17(C) tell you what to do, but not why.